2 * Copyright (c) 2010-2022 Contributors to the openHAB project
4 * See the NOTICE file(s) distributed with this work for additional
7 * This program and the accompanying materials are made available under the
8 * terms of the Eclipse Public License 2.0 which is available at
9 * http://www.eclipse.org/legal/epl-2.0
11 * SPDX-License-Identifier: EPL-2.0
14 * The {@link Shelly1CoIoTVersion1} implements the parsing for CoIoT version 1
16 * @author Markus Michels - Initial contribution
18 package org.openhab.binding.shelly.internal.api1;
20 import static org.openhab.binding.shelly.internal.ShellyBindingConstants.*;
21 import static org.openhab.binding.shelly.internal.api1.Shelly1ApiJsonDTO.*;
22 import static org.openhab.binding.shelly.internal.util.ShellyUtils.*;
24 import java.util.List;
27 import org.eclipse.jdt.annotation.NonNullByDefault;
28 import org.eclipse.jdt.annotation.Nullable;
29 import org.openhab.binding.shelly.internal.api1.Shelly1CoapJSonDTO.CoIotDescrBlk;
30 import org.openhab.binding.shelly.internal.api1.Shelly1CoapJSonDTO.CoIotDescrSen;
31 import org.openhab.binding.shelly.internal.api1.Shelly1CoapJSonDTO.CoIotSensor;
32 import org.openhab.binding.shelly.internal.handler.ShellyColorUtils;
33 import org.openhab.binding.shelly.internal.handler.ShellyThingInterface;
34 import org.openhab.core.library.types.OnOffType;
35 import org.openhab.core.library.types.OpenClosedType;
36 import org.openhab.core.library.unit.SIUnits;
37 import org.openhab.core.library.unit.Units;
38 import org.openhab.core.types.State;
39 import org.openhab.core.types.UnDefType;
40 import org.slf4j.Logger;
41 import org.slf4j.LoggerFactory;
44 * The {@link Shelly1CoIoTVersion1} implements the parsing for CoIoT version 2
46 * @author Markus Michels - Initial contribution
49 public class Shelly1CoIoTVersion2 extends Shelly1CoIoTProtocol implements Shelly1CoIoTInterface {
50 private final Logger logger = LoggerFactory.getLogger(Shelly1CoIoTVersion2.class);
51 private int lastCfgCount = -1;
53 public Shelly1CoIoTVersion2(String thingName, ShellyThingInterface thingHandler, Map<String, CoIotDescrBlk> blkMap,
54 Map<String, CoIotDescrSen> sensorMap) {
55 super(thingName, thingHandler, blkMap, sensorMap);
59 public int getVersion() {
60 return Shelly1CoapJSonDTO.COIOT_VERSION_2;
64 * Process CoIoT status update message. If a status update is received, but the device description has not been
65 * received yet a GET is send to query device description.
67 * @param sensorUpdates Complete list of sensor updates
68 * @param sen The specific sensor update to handle
69 * @param updates Resulting updates (new updates will be added to input list)
72 public boolean handleStatusUpdate(List<CoIotSensor> sensorUpdates, CoIotDescrSen sen, int serial, CoIotSensor s,
73 Map<String, State> updates, ShellyColorUtils col) {
74 // first check the base implementation
75 if (super.handleStatusUpdate(sensorUpdates, sen, s, updates, col)) {
76 // process by the base class
80 // Process status information and convert into channel updates
81 // Integer rIndex = Integer.parseInt(sen.links) + 1;
82 int rIndex = getIdFromBlk(sen);
83 String rGroup = getProfile().numRelays <= 1 ? CHANNEL_GROUP_RELAY_CONTROL
84 : CHANNEL_GROUP_RELAY_CONTROL + rIndex;
85 String mGroup = profile.numMeters <= 1 ? CHANNEL_GROUP_METER
86 : CHANNEL_GROUP_METER + (profile.isEMeter ? getIdFromBlk(sen) : rIndex);
88 boolean processed = true;
89 double value = getDouble(s.value);
93 // Special handling for TRV, because it uses duplicate ID values with different meanings
95 case "3101": // current temp
96 updateChannel(updates, CHANNEL_GROUP_SENSOR, CHANNEL_SENSOR_TEMP,
97 toQuantityType(value, DIGITS_TEMP, SIUnits.CELSIUS));
99 case "3103": // target temp in C. 4/31, 999=unknown
100 updateChannel(updates, CHANNEL_GROUP_CONTROL, CHANNEL_CONTROL_SETTEMP,
101 toQuantityType(value, DIGITS_TEMP, SIUnits.CELSIUS));
103 case "3116": // S, valveError, 0/1
105 thingHandler.postEvent(ALARM_TYPE_VALVE_ERROR, false);
108 case "3117": // S, mode, 0-5 (0=disabled)
109 value = getDouble(s.value).intValue();
110 updateChannel(updates, CHANNEL_GROUP_CONTROL, CHANNEL_CONTROL_PROFILE,
111 getStringType(profile.getValueProfile(0, (int) value)));
112 updateChannel(updates, CHANNEL_GROUP_CONTROL, CHANNEL_CONTROL_SCHEDULE, getOnOff(value > 0));
114 case "3118": // Valve state
115 updateChannel(updates, CHANNEL_GROUP_SENSOR, CHANNEL_SENSOR_STATE,
116 value != 0 ? OpenClosedType.OPEN : OpenClosedType.CLOSED);
118 case "3121": // valvePos, Type=S, Range=0/100;
119 boolean updated = updateChannel(updates, CHANNEL_GROUP_CONTROL, CHANNEL_CONTROL_POSITION,
120 s.value != -1 ? toQuantityType(getDouble(s.value), 0, Units.PERCENT) : UnDefType.UNDEF);
121 if (updated && s.value >= 0 && s.value != thingHandler.getChannelDouble(CHANNEL_GROUP_CONTROL,
122 CHANNEL_CONTROL_POSITION)) {
123 logger.debug("{}: Valve position changed, force update", thingName);
124 thingHandler.requestUpdates(1, false);
140 case "3106": // L, luminosity, lux, U32, -1
141 case "3110": // S, luminosityLevel, dark/twilight/bright, "unknown"=unknown
142 case "3111": // B, battery, 0-100%, unknown -1
143 case "3112": // S, charger, 0/1
144 case "3115": // S, sensorError, 0/1
145 // processed by base handler
148 case "6109": // P, overpowerValue, W, U32
150 // Relay: S, mode, relay/roller or
151 // Dimmer: S, mode, color/white
152 // skip, could check against thing mode...
155 case "1101": // relay_0: output, 0/1
156 case "1201": // relay_1: output, 0/1
157 case "1301": // relay_2: output, 0/1
158 case "1401": // relay_3: output, 0/1
159 updatePower(profile, updates, rIndex, sen, s, sensorUpdates);
161 case "1102": // roler_0: S, roller, open/close/stop -> roller state
162 updateChannel(updates, CHANNEL_GROUP_ROL_CONTROL, CHANNEL_ROL_CONTROL_STATE, getStringType(s.valueStr));
164 case "1103": // roller_0: S, rollerPos, 0-100, unknown -1
165 int pos = Math.max(SHELLY_MIN_ROLLER_POS, Math.min((int) value, SHELLY_MAX_ROLLER_POS));
166 logger.debug("{}: CoAP update roller position: control={}, position={}", thingName,
167 SHELLY_MAX_ROLLER_POS - pos, pos);
168 updateChannel(updates, CHANNEL_GROUP_ROL_CONTROL, CHANNEL_ROL_CONTROL_CONTROL,
169 toQuantityType((double) (SHELLY_MAX_ROLLER_POS - pos), Units.PERCENT));
170 updateChannel(updates, CHANNEL_GROUP_ROL_CONTROL, CHANNEL_ROL_CONTROL_POS,
171 toQuantityType((double) pos, Units.PERCENT));
173 case "1105": // Gas: S, valve, closed/opened/not_connected/failure/closing/opening/checking or unknown
174 updateChannel(updates, CHANNEL_GROUP_SENSOR, CHANNEL_SENSOR_VALVE, getStringType(s.valueStr));
177 case "2101": // Input_0: S, input, 0/1
178 case "2201": // Input_1: S, input, 0/1
179 case "2301": // Input_2: S, input, 0/1
180 case "2401": // Input_3: S, input, 0/1
181 handleInput(sen, s, rGroup, updates);
183 case "2102": // Input_0: EV, inputEvent, S/SS/SSS/L
184 case "2202": // Input_1: EV, inputEvent
185 case "2302": // Input_2: EV, inputEvent
186 case "2402": // Input_3: EV, inputEvent
187 handleInputEvent(sen, getString(s.valueStr), -1, serial, updates);
189 case "2103": // EVC, inputEventCnt, U16
190 case "2203": // EVC, inputEventCnt, U16
191 case "2303": // EVC, inputEventCnt, U16
192 case "2403": // EVC, inputEventCnt, U16
193 handleInputEvent(sen, "", getInteger((int) s.value), serial, updates);
195 case "3101": // sensor_0: T, extTemp, C, -55/125; unknown 999
196 case "3201": // sensor_1: T, extTemp, C, -55/125; unknown 999
197 case "3301": // sensor_2: T, extTemp, C, -55/125; unknown 999
198 int idx = getExtTempId(sen.id);
200 // H&T, Fllod, DW only have 1 channel, 1/1PM with Addon have up to to 3 sensors
201 String channel = profile.isSensor ? CHANNEL_SENSOR_TEMP : CHANNEL_SENSOR_TEMP + idx;
202 // Some devices report values = -999 or 99 during fw update
203 updateChannel(updates, CHANNEL_GROUP_SENSOR, channel,
204 toQuantityType(value, DIGITS_TEMP, SIUnits.CELSIUS));
206 logger.debug("{}: Unable to get extSensorId {} from {}/{}", thingName, sen.id, sen.type, sen.desc);
209 case "3104": // T, deviceTemp, Celsius -40/300; 999=unknown
210 if ("targetTemp".equalsIgnoreCase(sen.desc)) {
212 break; // target temp in F-> ignore
214 // sensor_0: T, internalTemp, F, 39/88, unknown 999
215 updateChannel(updates, CHANNEL_GROUP_DEV_STATUS, CHANNEL_DEVST_ITEMP,
216 toQuantityType(value, DIGITS_NONE, SIUnits.CELSIUS));
218 case "3102": // sensor_0: T, extTemp, F, -67/257, unknown 999
219 case "3202": // sensor_1: T, extTemp, F, -67/257, unknown 999
220 case "3302": // sensor_2: T, extTemp, F, -67/257, unknown 999
221 case "3105": // T, deviceTemp, Fahrenheit -40/572
222 // skip, we use only C
225 case "3107": // C, Gas concentration, U16
226 updateChannel(updates, CHANNEL_GROUP_SENSOR, CHANNEL_SENSOR_PPM, getDecimal(s.value));
228 case "3108": // DW: S, dwIsOpened, 0/1, -1=unknown
230 updateChannel(updates, CHANNEL_GROUP_SENSOR, CHANNEL_SENSOR_STATE,
231 value != 0 ? OpenClosedType.OPEN : OpenClosedType.CLOSED);
233 logger.debug("{}: Sensor error reported, check device, battery and installation", thingName);
236 case "3109": // S, tilt, 0-180deg, -1
237 updateChannel(updates, CHANNEL_GROUP_SENSOR, CHANNEL_SENSOR_TILT,
238 toQuantityType(s.value, DIGITS_NONE, Units.DEGREE_ANGLE));
240 case "3113": // S, sensorOp, warmup/normal/fault
241 updateChannel(updates, CHANNEL_GROUP_SENSOR, CHANNEL_SENSOR_SSTATE, getStringType(s.valueStr));
243 case "3114": // S, selfTest, not_completed/completed/running/pending
244 updateChannel(updates, CHANNEL_GROUP_DEV_STATUS, CHANNEL_DEVST_SELFTTEST, getStringType(s.valueStr));
246 case "3117": // S, extInput, 0/1
247 handleInput(sen, s, rGroup, updates);
250 updateChannel(updates, mGroup, CHANNEL_SENSOR_VOLTAGE,
251 toQuantityType(getDouble(s.value), 2, Units.VOLT));
254 case "4101": // relay_0/light_0: P, power, W
255 case "4201": // relay_1/light_1: P, power, W
256 case "4301": // relay_2/light_2: P, power, W
257 case "4401": // relay_3/light_3: P, power, W
258 case "4105": // emeter_0: P, power, W
259 case "4205": // emeter_1: P, power, W
260 case "4305": // emeter_2: P, power, W
261 case "4102": // roller_0: P, rollerPower, W, 0-2300, unknown -1
262 case "4202": // roller_1: P, rollerPower, W, 0-2300, unknown -1
263 updateChannel(updates, mGroup, CHANNEL_METER_CURRENTWATTS,
264 toQuantityType(s.value, DIGITS_WATT, Units.WATT));
265 if (!profile.isRGBW2 && !profile.isRoller) {
266 // only for regular, not-aggregated meters
267 updateChannel(updates, mGroup, CHANNEL_LAST_UPDATE, getTimestamp());
271 case "4103": // relay_0: E, energy, Wmin, U32
272 case "4203": // relay_1: E, energy, Wmin, U32
273 case "4303": // relay_2: E, energy, Wmin, U32
274 case "4403": // relay_3: E, energy, Wmin, U32
275 case "4104": // roller_0: E, rollerEnergy, Wmin, U32, -1
276 case "4204": // roller_0: E, rollerEnergy, Wmin, U32, -1
277 case "4106": // emeter_0: E, energy, Wh, U32
278 case "4206": // emeter_1: E, energy, Wh, U32
279 case "4306": // emeter_2: E, energy, Wh, U32
280 double total = profile.isEMeter ? s.value / 1000 : s.value / 60 / 1000;
281 updateChannel(updates, mGroup, CHANNEL_METER_TOTALKWH,
282 toQuantityType(total, DIGITS_KWH, Units.KILOWATT_HOUR));
285 case "4107": // emeter_0: E, energyReturned, Wh, U32, -1
286 case "4207": // emeter_1: E, energyReturned, Wh, U32, -1
287 case "4307": // emeter_2: E, energyReturned, Wh, U32, -1
288 updateChannel(updates, mGroup, CHANNEL_EMETER_TOTALRET,
289 toQuantityType(getDouble(s.value) / 1000, DIGITS_KWH, Units.KILOWATT_HOUR));
292 case "4108": // emeter_0: V, voltage, 0-265V, U32, -1
293 case "4208": // emeter_1: V, voltage, 0-265V, U32, -1
294 case "4308": // emeter_2: V, voltage, 0-265V, U32, -1
295 updateChannel(updates, mGroup, CHANNEL_EMETER_VOLTAGE,
296 toQuantityType(getDouble(s.value), DIGITS_VOLT, Units.VOLT));
299 case "4109": // emeter_0: A, current, 0/120A, -1
300 case "4209": // emeter_1: A, current, 0/120A, -1
301 case "4309": // emeter_2: A, current, 0/120A, -1
302 updateChannel(updates, rGroup, CHANNEL_EMETER_CURRENT,
303 toQuantityType(getDouble(s.value), DIGITS_VOLT, Units.AMPERE));
306 case "4110": // emeter_0: S, powerFactor, 0/1, -1
307 case "4210": // emeter_1: S, powerFactor, 0/1, -1
308 case "4310": // emeter_2: S, powerFactor, 0/1, -1
309 updateChannel(updates, rGroup, CHANNEL_EMETER_PFACTOR, getDecimal(s.value));
312 case "5101": // {"I":5101,"T":"S","D":"brightness","R":"0/100","L":1},
313 case "5102": // {"I":5102,"T":"S","D":"gain","R":"0/100","L":1},
314 case "5103": // {"I":5103,"T":"S","D":"colorTemp","U":"K","R":"3000/6500","L":1},
315 case "5105": // {"I":5105,"T":"S","D":"red","R":"0/255","L":1},
316 case "5106": // {"I":5106,"T":"S","D":"green","R":"0/255","L":1},
317 case "5107": // {"I":5107,"T":"S","D":"blue","R":"0/255","L":1},
318 case "5108": // {"I":5108,"T":"S","D":"white","R":"0/255","L":1},
319 // already covered by base handler
322 case "6101": // A, overtemp, 0/1
324 thingHandler.postEvent(ALARM_TYPE_OVERTEMP, true);
327 case "6102": // relay_0: A, overpower, 0/1
328 case "6202": // relay_1: A, overpower, 0/1
329 case "6302": // relay_2: A, overpower, 0/1
330 case "6402": // relay_3: A, overpower, 0/1
332 thingHandler.postEvent(ALARM_TYPE_OVERPOWER, true);
335 case "6104": // relay_0: A, loadError, 0/1
336 case "6204": // relay_1: A, loadError, 0/1
337 case "6304": // relay_2: A, loadError, 0/1
338 case "6404": // relay_3: A, loadError, 0/1
340 thingHandler.postEvent(ALARM_TYPE_LOADERR, true);
343 case "6103": // roller_0: A, rollerStopReason, normal/safety_switch/obstacle/overpower
344 reason = getString(s.valueStr);
345 updateChannel(updates, CHANNEL_GROUP_ROL_CONTROL, CHANNEL_ROL_CONTROL_STOPR, getStringType(reason));
346 if (!reason.isEmpty() && !reason.equalsIgnoreCase(SHELLY_API_STOPR_NORMAL)) {
347 thingHandler.postEvent("ROLLER_" + reason.toUpperCase(), true);
349 case "6106": // A, flood, 0/1, -1
350 updateChannel(updates, CHANNEL_GROUP_SENSOR, CHANNEL_SENSOR_FLOOD,
351 value == 1 ? OnOffType.ON : OnOffType.OFF);
354 case "6107": // A, motion, 0/1, -1
355 // {"I":6107,"T":"A","D":"motion","R":["0/1","-1"],"L":1},
356 updateChannel(updates, CHANNEL_GROUP_SENSOR, CHANNEL_SENSOR_MOTION,
357 value == 1 ? OnOffType.ON : OnOffType.OFF);
359 case "3119": // Motion timestamp (timestamp os GMT, not adapted to the adapted timezone)
360 // {"I":3119,"T":"S","D":"timestamp","U":"s","R":["U32","-1"],"L":1},
362 updateChannel(updates, CHANNEL_GROUP_SENSOR, CHANNEL_SENSOR_MOTION_TS,
363 getTimestamp(getString("GMT"), (long) s.value));
366 case "3120": // motionActive (timestamp os GMT, not adapted to the adapted timezone)
367 // {"I":3120,"T":"S","D":"motionActive","R":["0/1","-1"],"L":1},
368 updateChannel(updates, CHANNEL_GROUP_SENSOR, CHANNEL_SENSOR_MOTION_ACT,
369 getTimestamp("GMT", (long) s.value));
372 case "6108": // A, gas, none/mild/heavy/test or unknown
373 updateChannel(updates, CHANNEL_GROUP_SENSOR, CHANNEL_SENSOR_ALARM_STATE, getStringType(s.valueStr));
375 case "6110": // A, vibration, 0/1, -1=unknown
376 updateChannel(updates, CHANNEL_GROUP_SENSOR, CHANNEL_SENSOR_VIBRATION,
377 s.value == 1 ? OnOffType.ON : OnOffType.OFF);
380 thingHandler.triggerChannel(CHANNEL_GROUP_DEV_STATUS, CHANNEL_DEVST_ALARM, EVENT_TYPE_VIBRATION);
383 case "9102": // EV, wakeupEvent, battery/button/periodic/poweron/sensor/ext_power, "unknown"=unknown
384 if (s.valueArray.size() > 0) {
385 thingHandler.updateWakeupReason(s.valueArray);
386 lastWakeup = (String) s.valueArray.get(0);
389 case "9103": // EVC, cfgChanged, U16
390 if (lastCfgCount == -1 || lastCfgCount != s.value) {
391 thingHandler.requestUpdates(1, true); // refresh config
393 lastCfgCount = (int) s.value;
403 public CoIotDescrSen fixDescription(@Nullable CoIotDescrSen sen, Map<String, CoIotDescrBlk> blkMap) {
404 return super.fixDescription(sen, blkMap);
407 private static final String ID_4101_DESCR = "{ \"I\":4101, \"T\":\"P\", \"D\":\"power\", \"U\": \"W\", \"R\":\"0/3500\", \"L\": 1}";
408 private static final String ID_4103_DESCR = "{ \"I\":4103, \"T\":\"E\", \"D\":\"energy\", \"U\": \"Wmin\", \"R\":\"U32\", \"L\": 1}";
411 public void completeMissingSensorDefinition(Map<String, CoIotDescrSen> sensorMap) {
412 if (profile.isDuo && profile.inColor) {
413 addSensor(sensorMap, "4101", ID_4101_DESCR);
414 addSensor(sensorMap, "4103", ID_4103_DESCR);
416 super.completeMissingSensorDefinition(sensorMap);