]> git.basschouten.com Git - openhab-addons.git/blob
438ba5a894f960269622a3f33ac8105b0aebfb27
[openhab-addons.git] /
1 /**
2  * Copyright (c) 2010-2023 Contributors to the openHAB project
3  *
4  * See the NOTICE file(s) distributed with this work for additional
5  * information.
6  *
7  * This program and the accompanying materials are made available under the
8  * terms of the Eclipse Public License 2.0 which is available at
9  * http://www.eclipse.org/legal/epl-2.0
10  *
11  * SPDX-License-Identifier: EPL-2.0
12  */
13 /**
14  * The {@link Shelly1CoIoTVersion1} implements the parsing for CoIoT version 1
15  *
16  * @author Markus Michels - Initial contribution
17  */
18 package org.openhab.binding.shelly.internal.api1;
19
20 import static org.openhab.binding.shelly.internal.ShellyBindingConstants.*;
21 import static org.openhab.binding.shelly.internal.api1.Shelly1ApiJsonDTO.*;
22 import static org.openhab.binding.shelly.internal.util.ShellyUtils.*;
23
24 import java.util.List;
25 import java.util.Map;
26
27 import org.eclipse.jdt.annotation.NonNullByDefault;
28 import org.eclipse.jdt.annotation.Nullable;
29 import org.openhab.binding.shelly.internal.api1.Shelly1CoapJSonDTO.CoIotDescrBlk;
30 import org.openhab.binding.shelly.internal.api1.Shelly1CoapJSonDTO.CoIotDescrSen;
31 import org.openhab.binding.shelly.internal.api1.Shelly1CoapJSonDTO.CoIotSensor;
32 import org.openhab.binding.shelly.internal.handler.ShellyColorUtils;
33 import org.openhab.binding.shelly.internal.handler.ShellyThingInterface;
34 import org.openhab.core.library.types.OnOffType;
35 import org.openhab.core.library.types.OpenClosedType;
36 import org.openhab.core.library.unit.SIUnits;
37 import org.openhab.core.library.unit.Units;
38 import org.openhab.core.types.State;
39 import org.openhab.core.types.UnDefType;
40 import org.slf4j.Logger;
41 import org.slf4j.LoggerFactory;
42
43 /**
44  * The {@link Shelly1CoIoTVersion1} implements the parsing for CoIoT version 2
45  *
46  * @author Markus Michels - Initial contribution
47  */
48 @NonNullByDefault
49 public class Shelly1CoIoTVersion2 extends Shelly1CoIoTProtocol implements Shelly1CoIoTInterface {
50     private final Logger logger = LoggerFactory.getLogger(Shelly1CoIoTVersion2.class);
51     private int lastCfgCount = -1;
52
53     public Shelly1CoIoTVersion2(String thingName, ShellyThingInterface thingHandler, Map<String, CoIotDescrBlk> blkMap,
54             Map<String, CoIotDescrSen> sensorMap) {
55         super(thingName, thingHandler, blkMap, sensorMap);
56     }
57
58     @Override
59     public int getVersion() {
60         return Shelly1CoapJSonDTO.COIOT_VERSION_2;
61     }
62
63     /**
64      * Process CoIoT status update message. If a status update is received, but the device description has not been
65      * received yet a GET is send to query device description.
66      *
67      * @param sensorUpdates Complete list of sensor updates
68      * @param sen The specific sensor update to handle
69      * @param updates Resulting updates (new updates will be added to input list)
70      */
71     @Override
72     public boolean handleStatusUpdate(List<CoIotSensor> sensorUpdates, CoIotDescrSen sen, int serial, CoIotSensor s,
73             Map<String, State> updates, ShellyColorUtils col) {
74         // first check the base implementation
75         if (super.handleStatusUpdate(sensorUpdates, sen, s, updates, col)) {
76             // process by the base class
77             return true;
78         }
79
80         // Process status information and convert into channel updates
81         // Integer rIndex = Integer.parseInt(sen.links) + 1;
82         int rIndex = getIdFromBlk(sen);
83         String rGroup = getProfile().numRelays <= 1 ? CHANNEL_GROUP_RELAY_CONTROL
84                 : CHANNEL_GROUP_RELAY_CONTROL + rIndex;
85         String mGroup = profile.numMeters <= 1 ? CHANNEL_GROUP_METER
86                 : CHANNEL_GROUP_METER + (profile.isEMeter ? getIdFromBlk(sen) : rIndex);
87
88         boolean processed = true;
89         double value = getDouble(s.value);
90         String reason = "";
91
92         if (profile.isTRV) {
93             // Special handling for TRV, because it uses duplicate ID values with different meanings
94             switch (sen.id) {
95                 case "3101": // current temp
96                     updateChannel(updates, CHANNEL_GROUP_SENSOR, CHANNEL_SENSOR_TEMP,
97                             toQuantityType(value, DIGITS_TEMP, SIUnits.CELSIUS));
98                     break;
99                 case "3103": // target temp in C. 4/31, 999=unknown
100                     updateChannel(updates, CHANNEL_GROUP_CONTROL, CHANNEL_CONTROL_SETTEMP,
101                             toQuantityType(value, DIGITS_TEMP, SIUnits.CELSIUS));
102                     break;
103                 case "3116": // S, valveError, 0/1
104                     if (s.value == 1) {
105                         thingHandler.postEvent(ALARM_TYPE_VALVE_ERROR, false);
106                     }
107                     break;
108                 case "3117": // S, mode, 0-5 (0=disabled)
109                     value = getDouble(s.value).intValue();
110                     updateChannel(updates, CHANNEL_GROUP_CONTROL, CHANNEL_CONTROL_PROFILE,
111                             getStringType(profile.getValueProfile(0, (int) value)));
112                     updateChannel(updates, CHANNEL_GROUP_CONTROL, CHANNEL_CONTROL_SCHEDULE, getOnOff(value > 0));
113                     break;
114                 case "3118": // Valve state
115                     updateChannel(updates, CHANNEL_GROUP_SENSOR, CHANNEL_SENSOR_STATE,
116                             value != 0 ? OpenClosedType.OPEN : OpenClosedType.CLOSED);
117                     break;
118                 case "3121": // valvePos, Type=S, Range=0/100;
119                     boolean updated = updateChannel(updates, CHANNEL_GROUP_CONTROL, CHANNEL_CONTROL_POSITION,
120                             s.value != -1 ? toQuantityType(getDouble(s.value), 0, Units.PERCENT) : UnDefType.UNDEF);
121                     if (updated && s.value >= 0 && s.value != thingHandler.getChannelDouble(CHANNEL_GROUP_CONTROL,
122                             CHANNEL_CONTROL_POSITION)) {
123                         logger.debug("{}: Valve position changed, force update", thingName);
124                         thingHandler.requestUpdates(1, false);
125                     }
126                     break;
127                 default:
128                     processed = false;
129             }
130         } else {
131             processed = false;
132         }
133
134         if (processed) {
135             return true;
136         }
137
138         processed = true;
139         switch (sen.id) {
140             case "3106": // L, luminosity, lux, U32, -1
141             case "3110": // S, luminosityLevel, dark/twilight/bright, "unknown"=unknown
142             case "3111": // B, battery, 0-100%, unknown -1
143             case "3112": // S, charger, 0/1
144             case "3115": // S, sensorError, 0/1
145                 // processed by base handler
146                 break;
147
148             case "6109": // P, overpowerValue, W, U32
149             case "9101":
150                 // Relay: S, mode, relay/roller or
151                 // Dimmer: S, mode, color/white
152                 // skip, could check against thing mode...
153                 break;
154
155             case "1101": // relay_0: output, 0/1
156             case "1201": // relay_1: output, 0/1
157             case "1301": // relay_2: output, 0/1
158             case "1401": // relay_3: output, 0/1
159                 updatePower(profile, updates, rIndex, sen, s, sensorUpdates);
160                 break;
161             case "1102": // roler_0: S, roller, open/close/stop -> roller state
162                 updateChannel(updates, CHANNEL_GROUP_ROL_CONTROL, CHANNEL_ROL_CONTROL_STATE, getStringType(s.valueStr));
163                 break;
164             case "1103": // roller_0: S, rollerPos, 0-100, unknown -1
165                 int pos = Math.max(SHELLY_MIN_ROLLER_POS, Math.min((int) value, SHELLY_MAX_ROLLER_POS));
166                 logger.debug("{}: CoAP update roller position: control={}, position={}", thingName,
167                         SHELLY_MAX_ROLLER_POS - pos, pos);
168                 updateChannel(updates, CHANNEL_GROUP_ROL_CONTROL, CHANNEL_ROL_CONTROL_CONTROL,
169                         toQuantityType((double) (SHELLY_MAX_ROLLER_POS - pos), Units.PERCENT));
170                 updateChannel(updates, CHANNEL_GROUP_ROL_CONTROL, CHANNEL_ROL_CONTROL_POS,
171                         toQuantityType((double) pos, Units.PERCENT));
172                 break;
173             case "1105": // Gas: S, valve, closed/opened/not_connected/failure/closing/opening/checking or unknown
174                 updateChannel(updates, CHANNEL_GROUP_SENSOR, CHANNEL_SENSOR_VALVE, getStringType(s.valueStr));
175                 break;
176
177             case "2101": // Input_0: S, input, 0/1
178             case "2201": // Input_1: S, input, 0/1
179             case "2301": // Input_2: S, input, 0/1
180             case "2401": // Input_3: S, input, 0/1
181                 handleInput(sen, s, rGroup, updates);
182                 break;
183             case "2102": // Input_0: EV, inputEvent, S/SS/SSS/L
184             case "2202": // Input_1: EV, inputEvent
185             case "2302": // Input_2: EV, inputEvent
186             case "2402": // Input_3: EV, inputEvent
187                 handleInputEvent(sen, getString(s.valueStr), -1, serial, updates);
188                 break;
189             case "2103": // EVC, inputEventCnt, U16
190             case "2203": // EVC, inputEventCnt, U16
191             case "2303": // EVC, inputEventCnt, U16
192             case "2403": // EVC, inputEventCnt, U16
193                 handleInputEvent(sen, "", getInteger((int) s.value), serial, updates);
194                 break;
195             case "3101": // sensor_0: T, extTemp, C, -55/125; unknown 999
196             case "3201": // sensor_1: T, extTemp, C, -55/125; unknown 999
197             case "3301": // sensor_2: T, extTemp, C, -55/125; unknown 999
198                 int idx = getExtTempId(sen.id);
199                 if (idx >= 0) {
200                     // H&T, Fllod, DW only have 1 channel, 1/1PM with Addon have up to to 3 sensors
201                     String channel = profile.isSensor ? CHANNEL_SENSOR_TEMP : CHANNEL_SENSOR_TEMP + idx;
202                     // Some devices report values = -999 or 99 during fw update
203                     updateChannel(updates, CHANNEL_GROUP_SENSOR, channel,
204                             toQuantityType(value, DIGITS_TEMP, SIUnits.CELSIUS));
205                 } else {
206                     logger.debug("{}: Unable to get extSensorId {} from {}/{}", thingName, sen.id, sen.type, sen.desc);
207                 }
208                 break;
209             case "3104": // T, deviceTemp, Celsius -40/300; 999=unknown
210                 if ("targetTemp".equalsIgnoreCase(sen.desc)) {
211
212                     break; // target temp in F-> ignore
213                 }
214                 // sensor_0: T, internalTemp, F, 39/88, unknown 999
215                 updateChannel(updates, CHANNEL_GROUP_DEV_STATUS, CHANNEL_DEVST_ITEMP,
216                         toQuantityType(value, DIGITS_NONE, SIUnits.CELSIUS));
217                 break;
218             case "3102": // sensor_0: T, extTemp, F, -67/257, unknown 999
219             case "3202": // sensor_1: T, extTemp, F, -67/257, unknown 999
220             case "3302": // sensor_2: T, extTemp, F, -67/257, unknown 999
221             case "3105": // T, deviceTemp, Fahrenheit -40/572
222                 // skip, we use only C
223                 break;
224
225             case "3107": // C, Gas concentration, U16
226                 updateChannel(updates, CHANNEL_GROUP_SENSOR, CHANNEL_SENSOR_PPM, getDecimal(s.value));
227                 break;
228             case "3108": // DW: S, dwIsOpened, 0/1, -1=unknown
229                 if (value != -1) {
230                     updateChannel(updates, CHANNEL_GROUP_SENSOR, CHANNEL_SENSOR_STATE,
231                             value != 0 ? OpenClosedType.OPEN : OpenClosedType.CLOSED);
232                 } else {
233                     logger.debug("{}: Sensor error reported, check device, battery and installation", thingName);
234                 }
235                 break;
236             case "3109": // S, tilt, 0-180deg, -1
237                 updateChannel(updates, CHANNEL_GROUP_SENSOR, CHANNEL_SENSOR_TILT,
238                         toQuantityType(s.value, DIGITS_NONE, Units.DEGREE_ANGLE));
239                 break;
240             case "3113": // S, sensorOp, warmup/normal/fault
241                 updateChannel(updates, CHANNEL_GROUP_SENSOR, CHANNEL_SENSOR_SSTATE, getStringType(s.valueStr));
242                 break;
243             case "3114": // S, selfTest, not_completed/completed/running/pending
244                 updateChannel(updates, CHANNEL_GROUP_DEV_STATUS, CHANNEL_DEVST_SELFTTEST, getStringType(s.valueStr));
245                 break;
246             case "3117": // S, extInput, 0/1
247                 handleInput(sen, s, rGroup, updates);
248                 break;
249             case "3118":
250                 updateChannel(updates, mGroup, CHANNEL_SENSOR_VOLTAGE,
251                         toQuantityType(getDouble(s.value), 2, Units.VOLT));
252                 break;
253
254             case "4101": // relay_0/light_0: P, power, W
255             case "4201": // relay_1/light_1: P, power, W
256             case "4301": // relay_2/light_2: P, power, W
257             case "4401": // relay_3/light_3: P, power, W
258             case "4105": // emeter_0: P, power, W
259             case "4205": // emeter_1: P, power, W
260             case "4305": // emeter_2: P, power, W
261             case "4102": // roller_0: P, rollerPower, W, 0-2300, unknown -1
262             case "4202": // roller_1: P, rollerPower, W, 0-2300, unknown -1
263                 updateChannel(updates, mGroup, CHANNEL_METER_CURRENTWATTS,
264                         toQuantityType(s.value, DIGITS_WATT, Units.WATT));
265                 if (!profile.isRGBW2 && !profile.isRoller) {
266                     // only for regular, not-aggregated meters
267                     updateChannel(updates, mGroup, CHANNEL_LAST_UPDATE, getTimestamp());
268                 }
269                 break;
270
271             case "4103": // relay_0: E, energy, Wmin, U32
272             case "4203": // relay_1: E, energy, Wmin, U32
273             case "4303": // relay_2: E, energy, Wmin, U32
274             case "4403": // relay_3: E, energy, Wmin, U32
275             case "4104": // roller_0: E, rollerEnergy, Wmin, U32, -1
276             case "4204": // roller_0: E, rollerEnergy, Wmin, U32, -1
277             case "4106": // emeter_0: E, energy, Wh, U32
278             case "4206": // emeter_1: E, energy, Wh, U32
279             case "4306": // emeter_2: E, energy, Wh, U32
280                 double total = profile.isEMeter ? s.value / 1000 : s.value / 60 / 1000;
281                 updateChannel(updates, mGroup, CHANNEL_METER_TOTALKWH,
282                         toQuantityType(total, DIGITS_KWH, Units.KILOWATT_HOUR));
283                 break;
284
285             case "4107": // emeter_0: E, energyReturned, Wh, U32, -1
286             case "4207": // emeter_1: E, energyReturned, Wh, U32, -1
287             case "4307": // emeter_2: E, energyReturned, Wh, U32, -1
288                 updateChannel(updates, mGroup, CHANNEL_EMETER_TOTALRET,
289                         toQuantityType(getDouble(s.value) / 1000, DIGITS_KWH, Units.KILOWATT_HOUR));
290                 break;
291
292             case "4108": // emeter_0: V, voltage, 0-265V, U32, -1
293             case "4208": // emeter_1: V, voltage, 0-265V, U32, -1
294             case "4308": // emeter_2: V, voltage, 0-265V, U32, -1
295                 updateChannel(updates, mGroup, CHANNEL_EMETER_VOLTAGE,
296                         toQuantityType(getDouble(s.value), DIGITS_VOLT, Units.VOLT));
297                 break;
298
299             case "4109": // emeter_0: A, current, 0/120A, -1
300             case "4209": // emeter_1: A, current, 0/120A, -1
301             case "4309": // emeter_2: A, current, 0/120A, -1
302                 updateChannel(updates, rGroup, CHANNEL_EMETER_CURRENT,
303                         toQuantityType(getDouble(s.value), DIGITS_VOLT, Units.AMPERE));
304                 break;
305
306             case "4110": // emeter_0: S, powerFactor, 0/1, -1
307             case "4210": // emeter_1: S, powerFactor, 0/1, -1
308             case "4310": // emeter_2: S, powerFactor, 0/1, -1
309                 updateChannel(updates, rGroup, CHANNEL_EMETER_PFACTOR, getDecimal(s.value));
310                 break;
311
312             case "5101": // {"I":5101,"T":"S","D":"brightness","R":"0/100","L":1},
313             case "5102": // {"I":5102,"T":"S","D":"gain","R":"0/100","L":1},
314             case "5103": // {"I":5103,"T":"S","D":"colorTemp","U":"K","R":"3000/6500","L":1},
315             case "5105": // {"I":5105,"T":"S","D":"red","R":"0/255","L":1},
316             case "5106": // {"I":5106,"T":"S","D":"green","R":"0/255","L":1},
317             case "5107": // {"I":5107,"T":"S","D":"blue","R":"0/255","L":1},
318             case "5108": // {"I":5108,"T":"S","D":"white","R":"0/255","L":1},
319                 // already covered by base handler
320                 break;
321
322             case "6101": // A, overtemp, 0/1
323                 if (s.value == 1) {
324                     thingHandler.postEvent(ALARM_TYPE_OVERTEMP, true);
325                 }
326                 break;
327             case "6102": // relay_0: A, overpower, 0/1
328             case "6202": // relay_1: A, overpower, 0/1
329             case "6302": // relay_2: A, overpower, 0/1
330             case "6402": // relay_3: A, overpower, 0/1
331                 if (s.value == 1) {
332                     thingHandler.postEvent(ALARM_TYPE_OVERPOWER, true);
333                 }
334                 break;
335             case "6104": // relay_0: A, loadError, 0/1
336             case "6204": // relay_1: A, loadError, 0/1
337             case "6304": // relay_2: A, loadError, 0/1
338             case "6404": // relay_3: A, loadError, 0/1
339                 if (s.value == 1) {
340                     thingHandler.postEvent(ALARM_TYPE_LOADERR, true);
341                 }
342                 break;
343             case "6103": // roller_0: A, rollerStopReason, normal/safety_switch/obstacle/overpower
344                 reason = getString(s.valueStr);
345                 updateChannel(updates, CHANNEL_GROUP_ROL_CONTROL, CHANNEL_ROL_CONTROL_STOPR, getStringType(reason));
346                 if (!reason.isEmpty() && !reason.equalsIgnoreCase(SHELLY_API_STOPR_NORMAL)) {
347                     thingHandler.postEvent("ROLLER_" + reason.toUpperCase(), true);
348                 }
349             case "6106": // A, flood, 0/1, -1
350                 updateChannel(updates, CHANNEL_GROUP_SENSOR, CHANNEL_SENSOR_FLOOD,
351                         value == 1 ? OnOffType.ON : OnOffType.OFF);
352                 break;
353
354             case "6107": // A, motion, 0/1, -1
355                 // {"I":6107,"T":"A","D":"motion","R":["0/1","-1"],"L":1},
356                 updateChannel(updates, CHANNEL_GROUP_SENSOR, CHANNEL_SENSOR_MOTION,
357                         value == 1 ? OnOffType.ON : OnOffType.OFF);
358                 break;
359             case "3119": // Motion timestamp (timestamp os GMT, not adapted to the adapted timezone)
360                 // {"I":3119,"T":"S","D":"timestamp","U":"s","R":["U32","-1"],"L":1},
361                 if (s.value != 0) {
362                     updateChannel(updates, CHANNEL_GROUP_SENSOR, CHANNEL_SENSOR_MOTION_TS,
363                             getTimestamp(getString("GMT"), (long) s.value));
364                 }
365                 break;
366             case "3120": // motionActive (timestamp os GMT, not adapted to the adapted timezone)
367                 // {"I":3120,"T":"S","D":"motionActive","R":["0/1","-1"],"L":1},
368                 updateChannel(updates, CHANNEL_GROUP_SENSOR, CHANNEL_SENSOR_MOTION_ACT,
369                         getTimestamp("GMT", (long) s.value));
370                 break;
371
372             case "6108": // A, gas, none/mild/heavy/test or unknown
373                 updateChannel(updates, CHANNEL_GROUP_SENSOR, CHANNEL_SENSOR_ALARM_STATE, getStringType(s.valueStr));
374                 break;
375             case "6110": // A, vibration, 0/1, -1=unknown
376                 updateChannel(updates, CHANNEL_GROUP_SENSOR, CHANNEL_SENSOR_VIBRATION,
377                         s.value == 1 ? OnOffType.ON : OnOffType.OFF);
378                 if (s.value == 1) {
379                     // post event
380                     thingHandler.triggerChannel(CHANNEL_GROUP_DEV_STATUS, CHANNEL_DEVST_ALARM, EVENT_TYPE_VIBRATION);
381                 }
382                 break;
383             case "9102": // EV, wakeupEvent, battery/button/periodic/poweron/sensor/ext_power, "unknown"=unknown
384                 if (s.valueArray.size() > 0) {
385                     thingHandler.updateWakeupReason(s.valueArray);
386                     lastWakeup = (String) s.valueArray.get(0);
387                 }
388                 break;
389             case "9103": // EVC, cfgChanged, U16
390                 if (lastCfgCount == -1 || lastCfgCount != s.value) {
391                     thingHandler.requestUpdates(1, true); // refresh config
392                 }
393                 lastCfgCount = (int) s.value;
394                 break;
395
396             default:
397                 processed = false;
398         }
399         return processed;
400     }
401
402     @Override
403     public CoIotDescrSen fixDescription(@Nullable CoIotDescrSen sen, Map<String, CoIotDescrBlk> blkMap) {
404         return super.fixDescription(sen, blkMap);
405     }
406
407     private static final String ID_4101_DESCR = "{ \"I\":4101, \"T\":\"P\", \"D\":\"power\",  \"U\": \"W\",    \"R\":\"0/3500\", \"L\": 1}";
408     private static final String ID_4103_DESCR = "{ \"I\":4103, \"T\":\"E\", \"D\":\"energy\", \"U\": \"Wmin\", \"R\":\"U32\", \"L\": 1}";
409
410     @Override
411     public void completeMissingSensorDefinition(Map<String, CoIotDescrSen> sensorMap) {
412         if (profile.isDuo && profile.inColor) {
413             addSensor(sensorMap, "4101", ID_4101_DESCR);
414             addSensor(sensorMap, "4103", ID_4103_DESCR);
415         }
416         super.completeMissingSensorDefinition(sensorMap);
417     }
418 }