2 * Copyright (c) 2010-2022 Contributors to the openHAB project
4 * See the NOTICE file(s) distributed with this work for additional
7 * This program and the accompanying materials are made available under the
8 * terms of the Eclipse Public License 2.0 which is available at
9 * http://www.eclipse.org/legal/epl-2.0
11 * SPDX-License-Identifier: EPL-2.0
13 package org.openhab.binding.miele.internal.handler;
15 import static org.openhab.binding.miele.internal.MieleBindingConstants.MIELE_DEVICE_CLASS_WASHING_MACHINE;
16 import static org.openhab.binding.miele.internal.MieleBindingConstants.POWER_CONSUMPTION_CHANNEL_ID;
17 import static org.openhab.binding.miele.internal.MieleBindingConstants.WATER_CONSUMPTION_CHANNEL_ID;
19 import java.math.BigDecimal;
21 import org.eclipse.jdt.annotation.NonNullByDefault;
22 import org.openhab.binding.miele.internal.api.dto.DeviceProperty;
23 import org.openhab.binding.miele.internal.exceptions.MieleRpcException;
24 import org.openhab.core.i18n.LocaleProvider;
25 import org.openhab.core.i18n.TranslationProvider;
26 import org.openhab.core.library.types.OnOffType;
27 import org.openhab.core.library.types.QuantityType;
28 import org.openhab.core.library.unit.Units;
29 import org.openhab.core.thing.ChannelUID;
30 import org.openhab.core.thing.Thing;
31 import org.openhab.core.types.Command;
32 import org.openhab.core.types.RefreshType;
33 import org.slf4j.Logger;
34 import org.slf4j.LoggerFactory;
36 import com.google.gson.JsonElement;
39 * The {@link WashingMachineHandler} is responsible for handling commands,
40 * which are sent to one of the channels
42 * @author Karel Goderis - Initial contribution
43 * @author Kai Kreuzer - fixed handling of REFRESH commands
44 * @author Martin Lepsy - fixed handling of empty JSON results
45 * @author Jacob Laursen - Fixed multicast and protocol support (ZigBee/LAN), added power/water consumption channels
48 public class WashingMachineHandler extends MieleApplianceHandler<WashingMachineChannelSelector>
49 implements ExtendedDeviceStateListener {
51 private static final int POWER_CONSUMPTION_BYTE_POSITION = 51;
52 private static final int WATER_CONSUMPTION_BYTE_POSITION = 53;
53 private static final int EXTENDED_STATE_MIN_SIZE_BYTES = 54;
55 private final Logger logger = LoggerFactory.getLogger(WashingMachineHandler.class);
57 public WashingMachineHandler(Thing thing, TranslationProvider i18nProvider, LocaleProvider localeProvider) {
58 super(thing, i18nProvider, localeProvider, WashingMachineChannelSelector.class,
59 MIELE_DEVICE_CLASS_WASHING_MACHINE);
63 public void handleCommand(ChannelUID channelUID, Command command) {
64 super.handleCommand(channelUID, command);
66 String channelID = channelUID.getId();
67 String applianceId = this.applianceId;
68 if (applianceId == null) {
69 logger.warn("Command '{}' failed, appliance id is unknown", command);
73 WashingMachineChannelSelector selector = (WashingMachineChannelSelector) getValueSelectorFromChannelID(
75 JsonElement result = null;
80 MieleBridgeHandler bridgeHandler = getMieleBridgeHandler();
81 if (bridgeHandler == null) {
82 logger.warn("Command '{}' failed, missing bridge handler", command);
85 if (command.equals(OnOffType.ON)) {
86 result = bridgeHandler.invokeOperation(applianceId, modelID, "start");
87 } else if (command.equals(OnOffType.OFF)) {
88 result = bridgeHandler.invokeOperation(applianceId, modelID, "stop");
93 if (!(command instanceof RefreshType)) {
94 logger.debug("{} is a read-only channel that does not accept commands",
95 selector.getChannelID());
100 if (result != null && isResultProcessable(result)) {
101 logger.debug("Result of operation is {}", result.getAsString());
103 } catch (IllegalArgumentException e) {
105 "An error occurred while trying to set the read-only variable associated with channel '{}' to '{}'",
106 channelID, command.toString());
107 } catch (MieleRpcException e) {
108 Throwable cause = e.getCause();
110 logger.warn("An error occurred while trying to invoke operation: {}", e.getMessage());
112 logger.warn("An error occurred while trying to invoke operation: {} -> {}", e.getMessage(),
119 public void onAppliancePropertyChanged(DeviceProperty dp) {
120 super.onAppliancePropertyChanged(dp);
121 updateSwitchStartStopFromState(dp);
124 public void onApplianceExtendedStateChanged(byte[] extendedDeviceState) {
125 if (extendedDeviceState.length < EXTENDED_STATE_MIN_SIZE_BYTES) {
126 logger.debug("Insufficient extended state data to extract consumption values: {}", extendedDeviceState);
130 BigDecimal kiloWattHoursTenths = BigDecimal
131 .valueOf(extendedDeviceState[POWER_CONSUMPTION_BYTE_POSITION] & 0xff);
132 var kiloWattHours = new QuantityType<>(kiloWattHoursTenths.divide(BigDecimal.valueOf(10)), Units.KILOWATT_HOUR);
133 updateExtendedState(POWER_CONSUMPTION_CHANNEL_ID, kiloWattHours);
135 var litres = new QuantityType<>(BigDecimal.valueOf(extendedDeviceState[WATER_CONSUMPTION_BYTE_POSITION] & 0xff),
137 updateExtendedState(WATER_CONSUMPTION_CHANNEL_ID, litres);