2 * Copyright (c) 2010-2022 Contributors to the openHAB project
4 * See the NOTICE file(s) distributed with this work for additional
7 * This program and the accompanying materials are made available under the
8 * terms of the Eclipse Public License 2.0 which is available at
9 * http://www.eclipse.org/legal/epl-2.0
11 * SPDX-License-Identifier: EPL-2.0
13 package org.openhab.binding.miele.internal.handler;
15 import static org.openhab.binding.miele.internal.MieleBindingConstants.MIELE_DEVICE_CLASS_DISHWASHER;
16 import static org.openhab.binding.miele.internal.MieleBindingConstants.POWER_CONSUMPTION_CHANNEL_ID;
17 import static org.openhab.binding.miele.internal.MieleBindingConstants.WATER_CONSUMPTION_CHANNEL_ID;
19 import java.math.BigDecimal;
21 import org.eclipse.jdt.annotation.NonNullByDefault;
22 import org.openhab.binding.miele.internal.exceptions.MieleRpcException;
23 import org.openhab.core.i18n.LocaleProvider;
24 import org.openhab.core.i18n.TranslationProvider;
25 import org.openhab.core.library.types.OnOffType;
26 import org.openhab.core.library.types.QuantityType;
27 import org.openhab.core.library.unit.Units;
28 import org.openhab.core.thing.ChannelUID;
29 import org.openhab.core.thing.Thing;
30 import org.openhab.core.types.Command;
31 import org.openhab.core.types.RefreshType;
32 import org.slf4j.Logger;
33 import org.slf4j.LoggerFactory;
35 import com.google.gson.JsonElement;
38 * The {@link DishWasherHandler} is responsible for handling commands,
39 * which are sent to one of the channels
41 * @author Karel Goderis - Initial contribution
42 * @author Kai Kreuzer - fixed handling of REFRESH commands
43 * @author Martin Lepsy - fixed handling of empty JSON results
44 * @author Jacob Laursen - Fixed multicast and protocol support (ZigBee/LAN), added power/water consumption channels
47 public class DishWasherHandler extends MieleApplianceHandler<DishwasherChannelSelector>
48 implements ExtendedDeviceStateListener {
50 private static final int POWER_CONSUMPTION_BYTE_POSITION = 16;
51 private static final int WATER_CONSUMPTION_BYTE_POSITION = 18;
52 private static final int EXTENDED_STATE_MIN_SIZE_BYTES = 19;
54 private final Logger logger = LoggerFactory.getLogger(DishWasherHandler.class);
56 public DishWasherHandler(Thing thing, TranslationProvider i18nProvider, LocaleProvider localeProvider) {
57 super(thing, i18nProvider, localeProvider, DishwasherChannelSelector.class, MIELE_DEVICE_CLASS_DISHWASHER);
61 public void handleCommand(ChannelUID channelUID, Command command) {
62 super.handleCommand(channelUID, command);
64 String channelID = channelUID.getId();
65 String applianceId = this.applianceId;
66 if (applianceId == null) {
67 logger.warn("Command '{}' failed, appliance id is unknown", command);
71 DishwasherChannelSelector selector = (DishwasherChannelSelector) getValueSelectorFromChannelID(channelID);
72 JsonElement result = null;
77 MieleBridgeHandler bridgeHandler = getMieleBridgeHandler();
78 if (bridgeHandler == null) {
79 logger.warn("Command '{}' failed, missing bridge handler", command);
82 if (command.equals(OnOffType.ON)) {
83 result = bridgeHandler.invokeOperation(applianceId, modelID, "start");
84 } else if (command.equals(OnOffType.OFF)) {
85 result = bridgeHandler.invokeOperation(applianceId, modelID, "stop");
90 if (!(command instanceof RefreshType)) {
91 logger.debug("{} is a read-only channel that does not accept commands",
92 selector.getChannelID());
97 if (result != null && isResultProcessable(result)) {
98 logger.debug("Result of operation is {}", result.getAsString());
100 } catch (IllegalArgumentException e) {
102 "An error occurred while trying to set the read-only variable associated with channel '{}' to '{}'",
103 channelID, command.toString());
104 } catch (MieleRpcException e) {
105 Throwable cause = e.getCause();
107 logger.warn("An error occurred while trying to invoke operation: {}", e.getMessage());
109 logger.warn("An error occurred while trying to invoke operation: {} -> {}", e.getMessage(),
115 public void onApplianceExtendedStateChanged(byte[] extendedDeviceState) {
116 if (extendedDeviceState.length < EXTENDED_STATE_MIN_SIZE_BYTES) {
117 logger.debug("Insufficient extended state data to extract consumption values: {}", extendedDeviceState);
121 BigDecimal kiloWattHoursTenths = BigDecimal
122 .valueOf(extendedDeviceState[POWER_CONSUMPTION_BYTE_POSITION] & 0xff);
123 var kiloWattHours = new QuantityType<>(kiloWattHoursTenths.divide(BigDecimal.valueOf(10)), Units.KILOWATT_HOUR);
124 updateExtendedState(POWER_CONSUMPTION_CHANNEL_ID, kiloWattHours);
126 BigDecimal decilitres = BigDecimal.valueOf(extendedDeviceState[WATER_CONSUMPTION_BYTE_POSITION] & 0xff);
127 var litres = new QuantityType<>(decilitres.divide(BigDecimal.valueOf(10)), Units.LITRE);
128 updateExtendedState(WATER_CONSUMPTION_CHANNEL_ID, litres);