2 * Copyright (c) 2010-2021 Contributors to the openHAB project
4 * See the NOTICE file(s) distributed with this work for additional
7 * This program and the accompanying materials are made available under the
8 * terms of the Eclipse Public License 2.0 which is available at
9 * http://www.eclipse.org/legal/epl-2.0
11 * SPDX-License-Identifier: EPL-2.0
14 * The {@link ShellyCoIoTVersion1} implements the parsing for CoIoT version 1
16 * @author Markus Michels - Initial contribution
18 package org.openhab.binding.shelly.internal.coap;
20 import static org.openhab.binding.shelly.internal.ShellyBindingConstants.*;
21 import static org.openhab.binding.shelly.internal.api.ShellyApiJsonDTO.*;
22 import static org.openhab.binding.shelly.internal.util.ShellyUtils.*;
24 import java.util.List;
27 import org.eclipse.jdt.annotation.NonNullByDefault;
28 import org.openhab.binding.shelly.internal.coap.ShellyCoapJSonDTO.CoIotDescrBlk;
29 import org.openhab.binding.shelly.internal.coap.ShellyCoapJSonDTO.CoIotDescrSen;
30 import org.openhab.binding.shelly.internal.coap.ShellyCoapJSonDTO.CoIotSensor;
31 import org.openhab.binding.shelly.internal.handler.ShellyBaseHandler;
32 import org.openhab.core.library.types.OnOffType;
33 import org.openhab.core.library.types.OpenClosedType;
34 import org.openhab.core.library.unit.SIUnits;
35 import org.openhab.core.library.unit.Units;
36 import org.openhab.core.types.State;
37 import org.slf4j.Logger;
38 import org.slf4j.LoggerFactory;
41 * The {@link ShellyCoIoTVersion1} implements the parsing for CoIoT version 2
43 * @author Markus Michels - Initial contribution
46 public class ShellyCoIoTVersion2 extends ShellyCoIoTProtocol implements ShellyCoIoTInterface {
47 private final Logger logger = LoggerFactory.getLogger(ShellyCoIoTVersion2.class);
49 public ShellyCoIoTVersion2(String thingName, ShellyBaseHandler thingHandler, Map<String, CoIotDescrBlk> blkMap,
50 Map<String, CoIotDescrSen> sensorMap) {
51 super(thingName, thingHandler, blkMap, sensorMap);
55 public int getVersion() {
56 return ShellyCoapJSonDTO.COIOT_VERSION_2;
60 * Process CoIoT status update message. If a status update is received, but the device description has not been
61 * received yet a GET is send to query device description.
63 * @param devId device id included in the status packet
64 * @param payload CoAP payload (Json format), example: {"G":[[0,112,0]]}
65 * @param serial Serial for this request. If this the the same as last serial
66 * the update was already sent and processed so this one gets
70 public boolean handleStatusUpdate(List<CoIotSensor> sensorUpdates, CoIotDescrSen sen, CoIotSensor s,
71 Map<String, State> updates) {
72 // first check the base implementation
73 if (super.handleStatusUpdate(sensorUpdates, sen, s, updates)) {
74 // process by the base class
78 // Process status information and convert into channel updates
79 // Integer rIndex = Integer.parseInt(sen.links) + 1;
80 int rIndex = getIdFromBlk(sen);
81 String rGroup = getProfile().numRelays <= 1 ? CHANNEL_GROUP_RELAY_CONTROL
82 : CHANNEL_GROUP_RELAY_CONTROL + rIndex;
83 String mGroup = profile.numMeters == 1 ? CHANNEL_GROUP_METER
84 : CHANNEL_GROUP_METER + (profile.isEMeter ? getIdFromBlk(sen) : rIndex);
86 boolean processed = true;
87 double value = getDouble(s.value);
90 case "3103": // H, humidity, 0-100 percent, unknown 999
91 case "3106": // L, luminosity, lux, U32, -1
92 case "3109": // S, tilt, 0-180deg, -1
93 case "3110": // S, luminosityLevel, dark/twilight/bright, "unknown"=unknown
94 case "3111": // B, battery, 0-100%, unknown -1
95 case "3112": // S, charger, 0/1
96 case "3115": // S, sensorError, 0/1
97 case "5101": // S, brightness, 1-100%
98 // processed by base handler
100 case "6109": // P, overpowerValue, W, U32
102 // Relay: S, mode, relay/roller or
103 // Dimmer: S, mode, color/white
104 // skip, could check against thing mode...
107 case "1101": // S, output, 0/1
108 updatePower(profile, updates, rIndex, sen, s, sensorUpdates);
110 case "1102": // roler_0: S, roller, open/close/stop -> roller state
111 updateChannel(updates, CHANNEL_GROUP_ROL_CONTROL, CHANNEL_ROL_CONTROL_STATE, getStringType(s.valueStr));
113 case "1103": // roller_0: S, rollerPos, 0-100, unknown -1
114 int pos = Math.max(SHELLY_MIN_ROLLER_POS, Math.min((int) value, SHELLY_MAX_ROLLER_POS));
115 updateChannel(updates, CHANNEL_GROUP_ROL_CONTROL, CHANNEL_ROL_CONTROL_CONTROL,
116 toQuantityType(new Double(SHELLY_MAX_ROLLER_POS - pos), Units.PERCENT));
118 case "1105": // S, valvle, closed/opened/not_connected/failure/closing/opening/checking or unbknown
119 updateChannel(updates, CHANNEL_GROUP_SENSOR, CHANNEL_SENSOR_VALVE, getStringType(s.valueStr));
122 case "2101": // Input_0: S, input, 0/1
123 case "2201": // Input_1: S, input, 0/1
124 case "2301": // Input_2: S, input, 0/1
125 case "2401": // Input_3: S, input, 0/1
126 handleInput(sen, s, rGroup, updates);
128 case "2102": // Input_0: EV, inputEvent, S/SS/SSS/L
129 case "2202": // Input_1: EV, inputEvent
130 case "2302": // Input_2: EV, inputEvent
131 case "2402": // Input_3: EV, inputEvent
132 handleInputEvent(sen, getString(s.valueStr), -1, updates);
134 case "2103": // EVC, inputEventCnt, U16
135 case "2203": // EVC, inputEventCnt, U16
136 case "2303": // EVC, inputEventCnt, U16
137 case "2403": // EVC, inputEventCnt, U16
138 handleInputEvent(sen, "", getInteger((int) s.value), updates);
140 case "3101": // sensor_0: T, extTemp, C, -55/125; unknown 999
141 case "3201": // sensor_1: T, extTemp, C, -55/125; unknown 999
142 case "3301": // sensor_2: T, extTemp, C, -55/125; unknown 999
143 int idx = getExtTempId(sen.id);
145 // H&T, Fllod, DW only have 1 channel, 1/1PM with Addon have up to to 3 sensors
146 String channel = profile.isSensor ? CHANNEL_SENSOR_TEMP : CHANNEL_SENSOR_TEMP + idx;
147 updateChannel(updates, CHANNEL_GROUP_SENSOR, channel,
148 toQuantityType(value, DIGITS_TEMP, SIUnits.CELSIUS));
150 logger.debug("{}: Unable to get extSensorId {} from {}/{}", thingName, sen.id, sen.type, sen.desc);
153 case "3104": // T, deviceTemp, Celsius -40/300; 999=unknown
154 updateChannel(updates, CHANNEL_GROUP_DEV_STATUS, CHANNEL_DEVST_ITEMP,
155 toQuantityType(value, DIGITS_NONE, SIUnits.CELSIUS));
157 case "3102": // sensor_0: T, extTemp, F, -67/257, unknown 999
158 case "3202": // sensor_1: T, extTemp, F, -67/257, unknown 999
159 case "3302": // sensor_2: T, extTemp, F, -67/257, unknown 999
160 case "3105": // T, deviceTemp, Fahrenheit -40/572
161 // skip, we use only C
164 case "3107": // C, Gas concentration, U16
165 updateChannel(updates, CHANNEL_GROUP_SENSOR, CHANNEL_SENSOR_PPM, getDecimal(s.value));
167 case "3108": // DW: S, dwIsOpened, 0/1, -1=unknown
169 updateChannel(updates, CHANNEL_GROUP_SENSOR, CHANNEL_SENSOR_CONTACT,
170 value != 0 ? OpenClosedType.OPEN : OpenClosedType.CLOSED);
172 logger.debug("{}: Sensor error reported, check device, battery and installation", thingName);
175 case "3113": // S, sensorOp, warmup/normal/fault
176 updateChannel(updates, CHANNEL_GROUP_SENSOR, CHANNEL_SENSOR_SSTATE, getStringType(s.valueStr));
178 case "3114": // S, selfTest, not_completed/completed/running/pending
179 updateChannel(updates, CHANNEL_GROUP_DEV_STATUS, CHANNEL_DEVST_SELFTTEST, getStringType(s.valueStr));
181 case "3117": // S, extInput, 0/1
182 handleInput(sen, s, rGroup, updates);
185 case "4101": // relay_0: P, power, W
186 case "4201": // relay_1: P, power, W
187 case "4301": // relay_2: P, power, W
188 case "4401": // relay_3: P, power, W
189 case "4105": // emeter_0: P, power, W
190 case "4205": // emeter_1: P, power, W
191 case "4305": // emeter_2: P, power, W
192 case "4102": // roller_0: P, rollerPower, W, 0-2300, unknown -1
193 case "4202": // roller_1: P, rollerPower, W, 0-2300, unknown -1
194 updateChannel(updates, mGroup, CHANNEL_METER_CURRENTWATTS,
195 toQuantityType(s.value, DIGITS_WATT, Units.WATT));
196 updateChannel(updates, mGroup, CHANNEL_LAST_UPDATE, getTimestamp());
199 case "4103": // relay_0: E, energy, Wmin, U32
200 case "4203": // relay_1: E, energy, Wmin, U32
201 case "4303": // relay_2: E, energy, Wmin, U32
202 case "4403": // relay_3: E, energy, Wmin, U32
203 case "4104": // roller_0: E, rollerEnergy, Wmin, U32, -1
204 case "4204": // roller_0: E, rollerEnergy, Wmin, U32, -1
205 case "4106": // emeter_0: E, energy, Wh, U32
206 case "4206": // emeter_1: E, energy, Wh, U32
207 case "4306": // emeter_2: E, energy, Wh, U32
208 double total = profile.isEMeter ? s.value / 1000 : s.value / 60 / 1000;
209 updateChannel(updates, mGroup, CHANNEL_METER_TOTALKWH,
210 toQuantityType(total, DIGITS_KWH, Units.KILOWATT_HOUR));
213 case "4107": // emeter_0: E, energyReturned, Wh, U32, -1
214 case "4207": // emeter_1: E, energyReturned, Wh, U32, -1
215 case "4307": // emeter_2: E, energyReturned, Wh, U32, -1
216 updateChannel(updates, mGroup, CHANNEL_EMETER_TOTALRET,
217 toQuantityType(getDouble(s.value) / 1000, DIGITS_KWH, Units.KILOWATT_HOUR));
220 case "4108": // emeter_0: V, voltage, 0-265V, U32, -1
221 case "4208": // emeter_1: V, voltage, 0-265V, U32, -1
222 case "4308": // emeter_2: V, voltage, 0-265V, U32, -1
223 updateChannel(updates, mGroup, CHANNEL_EMETER_VOLTAGE,
224 toQuantityType(getDouble(s.value), DIGITS_VOLT, Units.VOLT));
227 case "4109": // emeter_0: A, current, 0/120A, -1
228 case "4209": // emeter_1: A, current, 0/120A, -1
229 case "4309": // emeter_2: A, current, 0/120A, -1
230 updateChannel(updates, rGroup, CHANNEL_EMETER_CURRENT,
231 toQuantityType(getDouble(s.value), DIGITS_VOLT, Units.AMPERE));
234 case "4110": // emeter_0: S, powerFactor, 0/1, -1
235 case "4210": // emeter_1: S, powerFactor, 0/1, -1
236 case "4310": // emeter_2: S, powerFactor, 0/1, -1
237 updateChannel(updates, rGroup, CHANNEL_EMETER_PFACTOR, getDecimal(s.value));
240 case "6101": // A, overtemp, 0/1
242 thingHandler.postEvent(ALARM_TYPE_OVERTEMP, true);
245 case "6102": // relay_0: A, overpower, 0/1
246 case "6202": // relay_1: A, overpower, 0/1
247 case "6302": // relay_2: A, overpower, 0/1
248 case "6402": // relay_3: A, overpower, 0/1
250 thingHandler.postEvent(ALARM_TYPE_OVERPOWER, true);
253 case "6104": // relay_0: A, loadError, 0/1
254 case "6204": // relay_1: A, loadError, 0/1
255 case "6304": // relay_2: A, loadError, 0/1
256 case "6404": // relay_3: A, loadError, 0/1
258 thingHandler.postEvent(ALARM_TYPE_LOADERR, true);
261 case "6103": // roller_0: A, rollerStopReason, normal/safety_switch/obstacle/overpower
262 reason = getString(s.valueStr);
263 updateChannel(updates, CHANNEL_GROUP_ROL_CONTROL, CHANNEL_ROL_CONTROL_STOPR, getStringType(reason));
264 if (!reason.isEmpty() && !reason.equalsIgnoreCase(SHELLY_API_STOPR_NORMAL)) {
265 thingHandler.postEvent("ROLLER_" + reason.toUpperCase(), true);
267 case "6106": // A, flood, 0/1, -1
268 updateChannel(updates, CHANNEL_GROUP_SENSOR, CHANNEL_SENSOR_FLOOD,
269 value == 1 ? OnOffType.ON : OnOffType.OFF);
271 case "6108": // A, gas, none/mild/heavy/test or unknown
272 updateChannel(updates, CHANNEL_GROUP_SENSOR, CHANNEL_SENSOR_ALARM_STATE, getStringType(s.valueStr));
274 case "6110": // A, vibration, 0/1, -1=unknown
275 updateChannel(updates, CHANNEL_GROUP_SENSOR, CHANNEL_SENSOR_VIBRATION,
276 value == 1 ? OnOffType.ON : OnOffType.OFF);
278 case "9102": // EV, wakeupEvent, battery/button/periodic/poweron/sensor/ext_power, "unknown"=unknown
279 thingHandler.updateWakeupReason(s.valueArray);
281 case "9103": // EVC, cfgChanged, U16
282 if ((lastCfgCount != -1) && (lastCfgCount != s.value)) {
283 thingHandler.requestUpdates(1, true); // refresh config
285 lastCfgCount = (int) s.value;