3 binding.heliosventilation.name = HeliosVentilation Binding
4 binding.heliosventilation.description = This is the binding for Helios Ventilation Systems KWL EC 200/300/500 Pro. It requires a connection to the RS485 bus used by the original remote controls KWL-FB (9417).
8 thing-type.heliosventilation.ventilation.label = HeliosVentilation (KWL)
9 thing-type.heliosventilation.ventilation.description = A domestic ventilation system (KWL) from Helios.
13 thing-type.config.heliosventilation.ventilation.pollPeriod.label = Poll Period
14 thing-type.config.heliosventilation.ventilation.pollPeriod.description = The poll period in seconds use 0 for no polling.
15 thing-type.config.heliosventilation.ventilation.serialPort.label = RS485 Interface Serial Port
16 thing-type.config.heliosventilation.ventilation.serialPort.description = The serial port name for the RS485 interfaces. Valid values are e.g. COM1 for Windows and /dev/ttyS0 or /dev/ttyUSB0 for Linux.
20 channel-type.heliosventilation.adjust_interval.label = Adjust Interval
21 channel-type.heliosventilation.bypass_temperature.label = Cell Bypass Temperature
22 channel-type.heliosventilation.bypass_temperature.description = Bypass temperature to disable the bypass function if outside temperature is below this threshold even if ventilation system is in summer mode.
23 channel-type.heliosventilation.cascade_mode.label = Cascaded ventilation system
24 channel-type.heliosventilation.co2_state.label = CO2 Control
25 channel-type.heliosventilation.co2_state.description = Control the ventilation system by CO2 sensor.
26 channel-type.heliosventilation.dc_fan_extract.label = Extract Fan
27 channel-type.heliosventilation.dc_fan_extract.description = Speed of the extract air fan (outgoing air).
28 channel-type.heliosventilation.dc_fan_supply.label = Supply Fan
29 channel-type.heliosventilation.dc_fan_supply.description = Speed of the supply air fan (incoming air).
30 channel-type.heliosventilation.extract_temperature.label = Extract Temperature
31 channel-type.heliosventilation.extract_temperature.description = Temperature measured in the extract (indoor, room temperature) air flow.
32 channel-type.heliosventilation.fanspeed.label = Fanspeed
33 channel-type.heliosventilation.hysteresis.label = Hysteresis
34 channel-type.heliosventilation.hysteresis.description = Hysteresis on defroster temperature.
35 channel-type.heliosventilation.maintenance_interval.label = Maintenance Interval
36 channel-type.heliosventilation.max_fanspeed.label = Maximum Fanspeed
37 channel-type.heliosventilation.min_fanspeed.label = Minimal Fanspeed
38 channel-type.heliosventilation.outgoing_temperature.label = Outgoing Temperature
39 channel-type.heliosventilation.outgoing_temperature.description = Temperature measured in the outgoing air flow.
40 channel-type.heliosventilation.outside_temperature.label = Outside Temperature
41 channel-type.heliosventilation.outside_temperature.description = Temperature measured in the outdoor air flow.
42 channel-type.heliosventilation.power_state.label = Power
43 channel-type.heliosventilation.power_state.description = State of the ventilation system.
44 channel-type.heliosventilation.preheat_temperature.label = Preheat Temperature
45 channel-type.heliosventilation.preheat_temperature.description = Set temperature for preheater.
46 channel-type.heliosventilation.radiator_type.label = Water radiator
47 channel-type.heliosventilation.radiator_type.description = Ventilation system with water radiator (ON) or electric radiator (OFF).
48 channel-type.heliosventilation.rh_level_auto.label = Auto Humidity level
49 channel-type.heliosventilation.rh_limit.label = RH Limit
50 channel-type.heliosventilation.rh_limit.description = Limit for relative humidity sensor.
51 channel-type.heliosventilation.rh_state.label = Humidity Control
52 channel-type.heliosventilation.rh_state.description = Control the ventilation system by humidity sensor.
53 channel-type.heliosventilation.set_temperature.label = Temperature
54 channel-type.heliosventilation.set_temperature.description = Set temperature for the supply air. Not used in all ventilation systems.
55 channel-type.heliosventilation.supply_stop_temperature.label = Supply Stop Temperature
56 channel-type.heliosventilation.supply_stop_temperature.description = Stop the supply fan if outside temperature is below this threshold.
57 channel-type.heliosventilation.supply_temperature.label = Supply Temperature
58 channel-type.heliosventilation.supply_temperature.description = Temperature measured in the supply (incoming) air flow.
59 channel-type.heliosventilation.switch_type.label = Boost switch
60 channel-type.heliosventilation.switch_type.description = External switch is used for boost (ON) or fireplace (OFF).
61 channel-type.heliosventilation.winter_state.label = Winter Mode
62 channel-type.heliosventilation.winter_state.description = Ventilation system is in winter mode and will not use bypass for cooling. If OFF, the bypass function will be used for cooling if the outside temperature is above the Cell Bypass Temperature.