]> git.basschouten.com Git - openhab-addons.git/commit
[knx] Allow all port names for serial interfaces (#13019)
authorHolger Friedrich <holgerfriedrich@users.noreply.github.com>
Sun, 26 Jun 2022 15:22:56 +0000 (17:22 +0200)
committerGitHub <noreply@github.com>
Sun, 26 Jun 2022 15:22:56 +0000 (17:22 +0200)
commit7c81a3db2f22b2733eb0aeb63d6ac48f9025d166
tree8f64fcecdc41ce08893d85fad8ffa3c6451b6d0b
parente9afa9f08aa8a1032fffd066b9e50811e128bb6e
[knx] Allow all port names for serial interfaces (#13019)

Starting with openHAB 3.3, the framework enforces using serial
ports which are detected by the system by default. This feature
is now disabled for the KNX addon to allow using symlinks to
ports as well.
Refers-to: openhab/openhab-core#3014
Signed-off-by: Holger Friedrich <mail@holger-friedrich.de>
bundles/org.openhab.binding.knx/src/main/resources/OH-INF/thing/serial.xml