<parameter name="passiveScanInterval" type="integer" min="4" max="16384">
<label>Passive Scan Interval</label>
<description>Passive scan interval defines the interval when scanning is re-started in units of 625us. Default is
- 6400ms.</description>
+ 6400 units (4000ms).</description>
<advanced>true</advanced>
<default>6400</default>
</parameter>
<parameter name="passiveScanWindow" type="integer" min="4" max="16384">
<label>Passive Scan Window</label>
<description>Passive scan Window defines how long time the scanner will listen on a certain frequency and try to
- pick up advertisement packets. Default is 6400ms.</description>
+ pick up advertisement packets. Default is 6400 units (4000ms).</description>
<advanced>true</advanced>
<default>6400</default>
</parameter>
<parameter name="activeScanInterval" type="integer" min="4" max="16384">
<label>Active Scan Interval</label>
<description>Active scan interval defines the interval when scanning is re-started in units of 625us. Default is
- 6400ms.</description>
+ 6400 units (4000ms).</description>
<advanced>true</advanced>
<default>6400</default>
</parameter>
<parameter name="activeScanWindow" type="integer" min="4" max="16384">
<label>Active Scan Window</label>
<description>Active scan Window defines how long time the scanner will listen on a certain frequency and try to pick
- up advertisement packets. Default is 6400ms.</description>
+ up advertisement packets. Default is 6400 units (4000ms).</description>
<advanced>true</advanced>
<default>6400</default>
</parameter>
<parameter name="connIntervalMin" type="integer" min="6" max="3200">
<label>Minimum Connection Interval</label>
- <description>Minimum connection interval in units of 1.25ms. Default is 100ms.</description>
+ <description>Minimum connection interval in units of 1.25ms. Default is 80 units (100ms).</description>
<advanced>true</advanced>
<default>80</default>
</parameter>
<parameter name="connIntervalMax" type="integer" min="6" max="3200">
<label>Maximum Connection Interval</label>
- <description>Maximum connection interval in units of 1.25ms. Default is 1000ms.</description>
+ <description>Maximum connection interval in units of 1.25ms. Default is 800 units (1000ms).</description>
<advanced>true</advanced>
<default>800</default>
</parameter>
<parameter name="connTimeout" type="integer" min="10" max="3200">
<label>Connection Supervision Timeout</label>
<description>Connection supervision timeout in units of 10ms defines how long the devices can be out of range before
- the connection is closed. Default is 10000ms.</description>
+ the connection is closed. Default is 1000 units (10000ms).</description>
<advanced>true</advanced>
<default>1000</default>
</parameter>