##### Thermo Central Unit integration known limitations
-- Read setPoint temperature and current mode
+- Read CU setPoint temperature when in WEEKLY / SCENARIO / PROTECTION / VACATION / HOLIDAY
- Set VACATION deadline date / time
- Central Unit Programming and Customisations settings (T1/2/3 temperature levels, setting date & time, weekly/scenarios/holiday profiles programming, etc.)
| Channel Type ID (channel ID) | Applies to Thing Type IDs | Item Type | Description | Read/Write | Advanced |
| ---------------------------- | -------------------------------------- | ------------------ | ------------------------------------------------------------------------------------------------------------------------------------- | :--------: | :------: |
-| `temperature` | `bus_thermo_zone`, `bus_thermo_sensor` | Number:Temperature | The zone currently sensed temperature | R | N |
-| `setpointTemperature` | `bus_thermo_zone`, `bus_thermo_cu` | Number:Temperature | The zone or Central Unit setpoint temperature | R/W | N |
+| `temperature` | `bus_thermo_zone`, `bus_thermo_sensor` | Number:Temperature | Currently sensed temperature for zone or sensor | R | N |
+| `setpointTemperature` | `bus_thermo_zone`, `bus_thermo_cu` | Number:Temperature | The zone or Central Unit manual setpoint temperature | R/W | N |
| `function` | `bus_thermo_zone`, `bus_thermo_cu` | String | The zone set thermo function (`COOLING`, `HEATING`, `GENERIC`) or the Central Unit thermo function (`COOLING`, `HEATING`) | R/W | N |
| `mode` | `bus_thermo_zone`, `bus_thermo_cu` | String | The zone set mode (`AUTO`, `MANUAL`, `OFF`, `PROTECTION`) or the Central Unit set mode (`WEEKLY`, `MANUAL`, `SCENARIO`, `HOLIDAY`, `VACATION`, `OFF`, `PROTECTION`) | R/W | N |
| `speedFanCoil` | `bus_thermo_zone` | String | The zone fancoil speed: `AUTO`, `SPEED_1`, `SPEED_2`, `SPEED_3` | R/W | N |
| `batteryStatus` | `bus_thermo_cu` | String | The Central Unit Battery status: `OK`, `KO` | R | Y |
| `weeklyProgram` | `bus_thermo_cu` | Number | The weekly program number (`1`, `2`, `3`) when Central Unit mode is `WEEKLY` | R/W | N |
| `scenarioProgram` | `bus_thermo_cu` | Number | The scenario program number (`1`, `2`, ... , `16`) when Central Unit mode is `SCENARIO` | R/W | N |
-| `vacationDays` | `bus_thermo_cu` | Number | Number of days 1-255 the Central Unit will be set to Antifreeze / Heat Protection temperature before returning to mode WEEKLY (read/write) | R/W | N |
-| `failureDiscovered` | `bus_thermo_cu` | Switch | Indicates if a Failure was discovered by the Central Unit: `ON`, `OFF` | R | Y |
-| `atLeastOneProbeOff` | `bus_thermo_cu` | Switch | Indicates if at least one probe is in OFF mode: `ON`, `OFF` | R | Y |
-| `atLeastOneProbeProtection` | `bus_thermo_cu` | Switch | Indicates if at least one probe is in PROTECTION mode: `ON`, `OFF` | R | Y |
-| `atLeastOneProbeManual` | `bus_thermo_cu` | Switch | Indicates if at least one probe is in MANUAL mode: `ON`, `OFF` | R | Y |
+| `vacationDays` | `bus_thermo_cu` | Number | Number of days 1-255 the Central Unit will be set to Anti-freeze / Heat Protection temperature before returning to mode WEEKLY | R/W | N |
+| `failureDiscovered` | `bus_thermo_cu` | Switch | Indicates if a Failure was discovered by the Central Unit (`ON`), or not (`OFF`) | R | Y |
+| `atLeastOneProbeOff` | `bus_thermo_cu` | Switch | Indicates if at least one probe is in OFF mode (`ON`) or not (`OFF`) | R | Y |
+| `atLeastOneProbeProtection` | `bus_thermo_cu` | Switch | Indicates if at least one probe is in PROTECTION mode (`ON`) or not (`OFF`) | R | Y |
+| `atLeastOneProbeManual` | `bus_thermo_cu` | Switch | Indicates if at least one probe is in MANUAL mode (`ON`) or not (`OFF`) | R | Y |
### Notes on channels
import org.openhab.core.types.Command;
import org.openhab.core.types.UnDefType;
import org.openwebnet4j.communication.OWNException;
+import org.openwebnet4j.communication.Response;
import org.openwebnet4j.message.BaseOpenMessage;
import org.openwebnet4j.message.FrameException;
import org.openwebnet4j.message.MalformedFrameException;
} else {
newTemp = ((DecimalType) command).doubleValue();
}
- try {
- send(Thermoregulation.requestWriteSetpointTemperature(getWhere(w.value()), newTemp, currentFunction));
- } catch (MalformedFrameException | OWNException e) {
- logger.warn("handleSetpoint() {}", e.getMessage());
+ if (newTemp >= 5.0 && newTemp <= 40.0) {
+ try {
+ Response res;
+ res = send(Thermoregulation.requestWriteSetpointTemperature(getWhere(w.value()), newTemp,
+ currentFunction));
+ // For zones no setPoint temperature confirmation message is returned from gw,
+ // so we update channel with current requested temp on successful response.
+ if (!isCentralUnit && res != null && res.isSuccess()) {
+ updateState(CHANNEL_TEMP_SETPOINT, getAsQuantityTypeOrNull(newTemp, SIUnits.CELSIUS));
+ currentSetPointTemp = newTemp;
+ }
+ } catch (MalformedFrameException | OWNException e) {
+ logger.warn("handleSetpoint() {}", e.getMessage());
+
+ }
+ } else {
+ logger.info("handleSetpoint() Setpoint temperature must be between 5°C and 40°C for thing {}",
+ getThing().getUID());
}
} else {
logger.warn("handleSetpoint() Unsupported command {} for thing {}", command, getThing().getUID());
DimThermo dim = (DimThermo) tmsg.getDim();
switch (dim) {
case TEMP_SETPOINT:
- case COMPLETE_PROBE_STATUS:
updateSetpoint(tmsg);
break;
+ case COMPLETE_PROBE_STATUS:
+ break;
case PROBE_TEMPERATURE:
case TEMPERATURE:
updateTemperature(tmsg);
}
String[] parameters = tmsg.getWhatParams();
if (parameters.length > 0 && tw.getType() == WhatThermoType.MANUAL) {
- // it should be like *4*110#TTTT*#0##
+ // manual setpoint frame should be like *4*110#TTTT*#0##
newTemp = Thermoregulation.decodeTemperature(parameters[0]);
logger.debug("updateSetpoint() parsed temperature from {}: {} ---> {}", tmsg.toStringVerbose(),
parameters[0], newTemp);