METER_VALVE_SWITCH_POSITION(new OBISIdentifier(0, 24, 4, 0), CosemDecimal.INSTANCE),
/* Electricity Meter */
- EMETER_EQUIPMENT_IDENTIFIER_V2_X(new OBISIdentifier(0, 42, 0, 0), CosemString.INSTANCE),
+ EMETER_EQUIPMENT_IDENTIFIER_V2_X(new OBISIdentifier(0, 42, 0, 0), CosemHexString.INSTANCE),
EMETER_EQUIPMENT_IDENTIFIER(new OBISIdentifier(0, 96, 1, 1), CosemHexString.INSTANCE),
EMETER_VALUE(new OBISIdentifier(0, 24, 2, 1, true), CosemDate.INSTANCE, CosemQuantity.KILO_WATT_HOUR),
EMETER_DELIVERY_TARIFF0(new OBISIdentifier(1, 1, 8, 0), CosemQuantity.KILO_WATT_HOUR),
EMETER_INSTANT_VOLTAGE_L3(new OBISIdentifier(1, 72, 7, 0), CosemQuantity.VOLT),
/* Gas Meter */
- GMETER_EQUIPMENT_IDENTIFIER_V2(new OBISIdentifier(7, 0, 0, 0), CosemString.INSTANCE),
+ GMETER_EQUIPMENT_IDENTIFIER_V2(new OBISIdentifier(7, 0, 0, 0), CosemHexString.INSTANCE),
GMETER_24H_DELIVERY_V2(new OBISIdentifier(7, 23, 1, 0), CosemQuantity.CUBIC_METRE, CosemDate.INSTANCE),
GMETER_24H_DELIVERY_COMPENSATED_V2(new OBISIdentifier(7, 23, 2, 0), CosemQuantity.CUBIC_METRE, CosemDate.INSTANCE),
GMETER_LAST_VALUE(new OBISIdentifier(0, 24, 2, 3), CosemDate.INSTANCE, CosemQuantity.CUBIC_METRE),
GMETER_VALVE_POSITION_V2_2(new OBISIdentifier(7, 24, 4, 0), CosemDecimal.INSTANCE),
/* Heating Meter */
- HMETER_EQUIPMENT_IDENTIFIER_V2_2(new OBISIdentifier(5, 0, 0, 0), CosemString.INSTANCE),
+ HMETER_EQUIPMENT_IDENTIFIER_V2_2(new OBISIdentifier(5, 0, 0, 0), CosemHexString.INSTANCE),
HMETER_VALUE_V2(new OBISIdentifier(5, 1, 0, 0), CosemQuantity.GIGA_JOULE, CosemDate.INSTANCE),
/* Cooling Meter */
- CMETER_EQUIPMENT_IDENTIFIER_V2_2(new OBISIdentifier(6, 0, 0, 0), CosemString.INSTANCE),
+ CMETER_EQUIPMENT_IDENTIFIER_V2_2(new OBISIdentifier(6, 0, 0, 0), CosemHexString.INSTANCE),
CMETER_VALUE_V2(new OBISIdentifier(6, 1, 0, 0), CosemQuantity.GIGA_JOULE, CosemDate.INSTANCE),
/* Water Meter */
- WMETER_EQUIPMENT_IDENTIFIER_V2_2(new OBISIdentifier(8, 0, 0, 0), CosemString.INSTANCE),
+ WMETER_EQUIPMENT_IDENTIFIER_V2_2(new OBISIdentifier(8, 0, 0, 0), CosemHexString.INSTANCE),
WMETER_VALUE_V2(new OBISIdentifier(8, 1, 0, 0), CosemQuantity.CUBIC_METRE, CosemDate.INSTANCE),
WMETER_VALUE_V3(new OBISIdentifier(0, 24, 3, 0, true), CosemQuantity.CUBIC_METRE),