[openwebnet] improved README for AUX and ENERGY (#13408)
authorM Valla <12682715+mvalla@users.noreply.github.com>
Sun, 18 Sep 2022 15:24:39 +0000 (17:24 +0200)
committerGitHub <noreply@github.com>
Sun, 18 Sep 2022 15:24:39 +0000 (17:24 +0200)
Signed-off-by: Massimo Valla <mvcode00@gmail.com>
Signed-off-by: Massimo Valla <mvcode00@gmail.com>
bundles/org.openhab.binding.openwebnet/README.md

index 70658a2a8368cd7d2a6057e133bfda1f7a3cccf7..dd76f85812bd9291a6504c38b4278400afc7d9a9 100644 (file)
@@ -47,7 +47,7 @@ The following Things and OpenWebNet `WHOs` are supported:
 | Auxiliary (AUX)               |     `9`     |                         `bus_aux`                          | AUX commands                                                     | Successfully tested: AUX configured for bulgrar-alarm unit 3486. Only sending AUX commands is supported                                                                                                    |
 | CEN & CEN+ Scenarios          | `15` & `25` | `bus_cen_scenario_control`, `bus_cenplus_scenario_control` | CEN/CEN+ scenarios events and virtual activation                 | Successfully tested: scenario buttons: HC/HD/HS/L/N/NT4680                                                                                                                                                 |
 | Dry Contact and IR Interfaces |    `25`     |                    `bus_dry_contact_ir`                    | Dry Contacts and IR Interfaces                                   | Successfully tested: contact interfaces F428 and 3477; IR sensors: HC/HD/HS/L/N/NT4610                                                                                                                     |
-| Energy Management             |    `18`     |                     `bus_energy_meter`                     | Energy Management                                                | Successfully tested: F520, F521                                                                                                                                                                            |
+| Energy Management             |    `18`     |                     `bus_energy_meter`                     | Energy Management                                                | Successfully tested: F520, F521. Partially tested: F522, F523                                                                                                                                                                            |
 
 ### For ZigBee (Radio)
 
@@ -126,12 +126,14 @@ For any manually added device, you must configure:
 
 - the associated gateway Thing (`Parent Bridge` menu)
 - the `where` configuration parameter (`OpenWebNet Address`): this is the OpenWebNet address configured for the device in the BTicino/Legrand system. This address can be found either on the device itself (Physical configuration, using jumpers in case of BUS) or through the MyHOME_Suite software (Virtual configuration). The address can have several formats depending on the device/system:
-    - example for BUS/SCS system, address Point-to-point with Area (A) and Light-point (PL):
+    - example for BUS/SCS system:
         - light device A=`2` (Area 2), PL=`4` (Light-point 4) --> `where="24"`
-        - light device A=`03`, PL=`11` on local bus --> `where="0311#4#01"`
+        - light device A=`03`, PL=`11` on local bus `01` --> `where="0311#4#01"`
         - CEN scenario A=`05`, PL=`12` --> `where="0512"`
-        - CEN+ scenario `5`: add a `2` before --> `where="25"`
-        - Dry Contact or IR Interface `99`: add a `3` before --> `where="399"`
+        - CEN+ scenario `5`: add `2` before --> `where="25"`
+        - Dry Contact or IR Interface `99`: add `3` before --> `where="399"`
+        - Energy meter F520/F521 numbered `1`: add `5` before  --> `where="51"`
+        - Energy meter F522/F523 numbered `4` add `7` before and `#0` after --> `where="74#0"`
     - example for ZigBee devices: `where=765432101#9`. The ID of the device (ADDR part) is usually written in hexadecimal on the device itself, for example `ID 0074CBB1`: convert to decimal (`7654321`) and add `01#9` at the end to obtain `where=765432101#9`. For 2-unit switch devices (`zb_on_off_switch2u`), last part should be `00#9`.
  
 
@@ -155,18 +157,36 @@ The (optional) Central Unit can be configured defining a `bus_themo_cu` Thing.
 
 #### Configuring Auxiliary (AUX)
 
-BUS Auxiliary commands (WHO=9) can be used to send on the BUS commands to control, for example, external devices or a BTcino Alarm system. 
+**NOTE** Receiving AUX messages originating from the BUS is not supported yet, only sending messages to the BUS is supported.
 
-To control a BTicino alarm system the alarm unit should be configured for example as follows:
+BUS Auxiliary commands (WHO=9) can be used to send on the BUS commands to control, for example, external devices or a BTicino Alarm system. 
 
-Antitheft -> Automations -> then toggle the Event option -> then select OPEN code
+The BTicino Alarm system **cannot** be controlled directly via the OpenWebNet protocol: the only possibility is to use AUX commands and configure your Alarm Control Panel (Automations section) to execute some commands (e.g. Activate alarm) when it receives a particular AUX OpenWebNet command.
+Alarm Control Automations allow you to run an OpenWebNet command when a particular event occurs; in this case, the events are changes of state of the AUX device (WHO=9) and the command to be performed is a burglar alarm command (WHO=5).
 
-- Type in the AUX command you want to set, e.g.\*9\*1\*4\## (where=4)
-- Type in the associated Open Web Net code you want to execute, e.g.\*5\*8*#1234## (engage alarm on zones 1,2,3,4).
+To configure Alarm Control Automations go to the menu:
 
-Please note that receiving AUX messages originating from the bus is not supported yet, only sending messages to the bus is supported.
+    Antitheft -> Automations
 
+##### Example configuration Automation 1: when AUX-1 goes OFF, then DISENGAGE all Zones
 
+With this configuration when AUX `where=1` goes OFF, the Alarm will execute the automantion and send command `*5*9##` to DISENGAGE all zones.
+
+    Name: Disengage all zones
+    Event: command OPEN = `*9*0*1##`
+    OPEN command to execute: `*5*9##`
+
+##### Example configuration Automation 2: when AUX-2 goes ON, then ENGAGE active Zones
+
+    Name: Engage active zones
+    Event: command OPEN = *9*1*2##
+    OPEN command to execute: *5*8##
+
+##### Example configuration Automation 3: when AUX-4 goes ON, then ENGAGE Zones 1, 2, 3, 4
+
+    Name: Engage zones 1-4
+    Event: command OPEN = *9*1*4##
+    OPEN command to execute: *5*8#1234##
 
 ### Central Unit integration missing points 
 
@@ -183,10 +203,10 @@ Please note that receiving AUX messages originating from the bus is not supporte
 | `switch` or `switch_01`/`02` for ZigBee | `bus_on_off_switch`, `zb_on_off_switch`, `zb_on_off_switch2u` | Switch        | To switch the device `ON` and `OFF`                                                                                                             |     R/W     |
 | `brightness`                            | `bus_dimmer`, `zb_dimmer`                                     | Dimmer        | To adjust the brightness value (Percent, `ON`, `OFF`)                                                                                           |     R/W     |
 | `shutter`                               | `bus_automation`                                              | Rollershutter | To activate roller shutters (`UP`, `DOWN`, `STOP`, Percent - [see Shutter position](#shutter-position))                                         |     R/W     |
-| `button#X`                              | `bus_cen_scenario_control`, `bus_cenplus_scenario_control`    | String        | Trigger channel for CEN/CEN+ scenario events [see possible values](#cen-cen-channels)                                                           | R (TRIGGER) |
+| `button#X`                              | `bus_cen_scenario_control`, `bus_cenplus_scenario_control`    | String        | Trigger channel for CEN/CEN+ scenario events [see possible values](#cen-cen-channels)                                                           | R (TRIGGER) |
 | `sensor`                                | `bus_dry_contact_ir`                                          | Switch        | Indicates if a Dry Contact Interface is `ON`/`OFF`, or if a IR Sensor is detecting movement (`ON`), or not  (`OFF`)                             |      R      |
 | `power`                                 | `bus_energy_meter`                                            | Number:Power  | The current active power usage from Energy Meter                                                                                                |      R      |
-| `aux`                                   | `bus_aux`                                                     | String        | Possible commands: ON,OFF,TOGGLE, STOP, UP,DOWN,ENABLED, DISABLED, RESET_GEN, RESET_BI, RESET_TRI. Only   'ON' and `OFF'  are supported for now |     R/W     |
+| `aux`                                   | `bus_aux`                                                     | String        | Possible commands: `ON`, `OFF`, `TOGGLE`, `STOP`, `UP`, `DOWN`, `ENABLED`, `DISABLED`, `RESET_GEN`, `RESET_BI`, `RESET_TRI`. Only `ON` and `OFF` are supported for now |     R/W     |
 
 ### Thermo channels
 
@@ -204,7 +224,7 @@ Please note that receiving AUX messages originating from the bus is not supporte
 | `remoteControl`              | `bus_thermo_cu`                        | String             | The Central Unit Remote Control status: `ENABLED`, `DISABLED`                                                                                                                           | R          | Y        |
 | `batteryStatus`              | `bus_thermo_cu`                        | String             | The Central Unit Battery status: `OK`, `KO`                                                                                                                                             | R          | Y        |
 | `weeklyProgram`              | `bus_thermo_cu`                        | Number             | The program number (`1`, `2`, `3`) when Central Unit mode is `WEEKLY`                                                                                                                   | R/W        | N        |
-| `scenarioProgram`            | `bus_thermo_cu`                        | Number             | The program number (`1`, `2`, .. ,  `16`) when Central Unit mode is `SCENARIO`                                                                                                          | R/W        | N        |
+| `scenarioProgram`            | `bus_thermo_cu`                        | Number             | The program number (`1`, `2`, ... ,  `16`) when Central Unit mode is `SCENARIO`                                                                                                          | R/W        | N        |
 | `failureDiscovered`          | `bus_thermo_cu`                        | Switch             | Indicates if a Failure was discovered by the Central Unit: `ON`, `OFF`                                                                                                                  | R          | Y        |
 | `atLeastOneProbeOff`         | `bus_thermo_cu`                        | Switch             | Indicates if at least one probe is in OFF mode: `ON`, `OFF`                                                                                                                             | R          | Y        |
 | `atLeastOneProbeProtection`  | `bus_thermo_cu`                        | Switch             | Indicates if at least one probe is in PROTECTION mode: `ON`, `OFF`                                                                                                                      | R          | Y        |